NC State University Home Page EHS&PS Home Page
Index of EHSC Services MSDS Services Training Services Emergency Information

Laser Hazard Assessment


 

ControlsClassifications 1 2a 2 3a 3b 4
Protective Housing (4.3.1) X X X X X X
Without Protective Housing (4.3.1.1)LSO shall establish Alternate Controls
Interlocks on Protective Housing (4.3.2) # # # X X X
EService Access Panel (4.3.3) ~ ~ ~ ~ ~ X
NKey Switch Master (4.3.4) - - - - O X
GViewing Portals (4.3.5.1) - - ^ ^ ^ ^
ICollecting Optics (4.3.5.2) - - ^ ^ ^ ^
NTotally Open Beam Path (4.3.6.1) - - - - X X
ELimited Open Beam Path (4.3.6.2) - - - - X X
ERemote Interlock Connector (4.3.7) - - - - O X
RBeam Stop or Attenuator (4.3.8) - - - O 0 X
IActivation Warning Systems (4.3.9) - - - - O X
NEmission Delay (4.3.9.1) - - - - - O
GClass 3b Laser Controlled Area (4.3.10.1) - - - - X -
Class 4 Laser Controlled Area (4.3.10.2) - - - - - X
Laser Outdoor Controls (4.3.11) - - - - X X
Temporary Laser Controlled Area* (4.3.12) ~ ~ ~ ~ X X
Remote Firing & Monitoring (4.3.13) - - - - - O
Labels (4.3.14) - X X X X X
Area Posting (4.3.15) - - O O X X
AAdministrative & Procedural Controls (4.4) - X X X X X
DStandard Operating Procedures (4.4.1) - - - - O X
M POutput Emission Limitations (4.4.2) - - -LSO Determination
I REducation and Training (4.4.3) - -O O X X
N OAuthorized Personnel (4.4.4) - - - - X X
I CAlignment Procedures (4.4.5) - - X X X X
S & EEye Protection (4.4.6) - - - - O X
T DSpectator Control (4.4.7) - - - - O X
R UService Personnel (4.4.8) ~ ~ ~ ~ X X
A RLaser Demonstration (4.5.1) - - X X X X
T ALaser Fiber Optics (4.5.2) - - X X X X
I L
V
E

LEGEND: X - Shall, - Should, - No Requirement, ~ Shall if Embedded Class 3b or Class 4, ^ Shall if MPE is exceeded, # Shall if embedded Class 3a, Class 3b, Class 4, * During Service Only